UNIMIG PAPR Welding Helmet TH3 U11152 combines an auto-darkening welding helmet with a battery-powered blower, breathing tube and P3 particulate filtration system. The blower supplies filtered air to the helmet for suitable welding environments, with adjustable airflow and a large viewing area.
Key Features
- Optical clarity: The 1/1/1/1 optical classification covers optical quality, light diffusion, shade consistency and angle dependence, supporting clear viewing with minimal distortion.
- EliteVision true-colour lens: The manual describes a lens that passes more visible colours to improve the view of the weld and help reduce eye fatigue.
- Large viewing area: The 100 × 83.4 mm view supports visibility of the work.
- Four arc sensors: Four positioned sensors detect the welding arc and activate darkening.
- Shade memory: Store up to three frequently used shade settings using the memory-state buttons.
- Grinding control: Switch between welding and grinding modes using the external control described on the current manufacturer page. Confirm the selected helmet’s controls and correct mode before welding.
- Powered particulate filtration: The manufacturer identifies the system as TH3 / P3 and lists inward leakage below 0.2%. P3 particle filtration and inward leakage are different measures; neither establishes general gas protection.
- Three airflow levels: Choose the manual-listed nominal 170, 200 or 230 L/min airflow settings to suit the approved system arrangement and work conditions.
- Rechargeable blower battery: A 4,400 mAh lithium-ion battery powers the blower, with a listed 3.5-hour charge time. It can be charged in the blower or separately using the specified charger.
- Status and fault warnings: Audible indications cover current overload, blocked air outlet, overheating, low battery and blocked filter, as well as normal operating actions.
Before You Buy
- Select respiratory protection for the actual contaminant and exposure assessment. The manual defines this configuration as P3 particulate protection; do not assume the supplied filter protects against gases or vapours. Use only UNIMIG-approved components in an approved configuration.
- Do not use with the blower switched off, in oxygen below 19.5%, unknown contaminants, immediately hazardous atmospheres, explosive atmospheres or high winds. Leave the contaminated area before removing the helmet or switching off the blower.
- The helmet is not head protection to AS/NZS 1801 and is not suitable for overhead welding, laser welding or laser cutting. It does not protect against explosives or corrosive liquids. Wear appropriate primary impact eye protection and other task-specific PPE.
- Check airflow, filter condition, battery charge, seals, breathing tube and auto-darkening operation before use. Keep sensors and cover plates clean; replace damaged parts. If the lens fails to darken, stop welding and check the mode and equipment.
- Use the supplied charger for this battery only, indoors and protected from moisture. Charge before first use and after storage longer than 15 days. Do not operate the blower while charging. Keep liquids out of the blower, filters and battery compartment.
- Use the operating limits for the complete system: the blower system has a narrower temperature range than the welding lens. Do not immerse the lens or use solvents on the helmet or lens; follow the full manual for cleaning, fit, storage and replacement procedures.
- Fit the face seal against the face with comfortable contact at the temples and adjust the headgear so it is stable. A seal that does not contact the face cannot provide the specified protection. Adjust the belt and shoulder straps so the blower is secure and accessible at the hips.
- Before each use, test airflow with the supplied tester as directed: the ball must rise above the marked line. Check the low-airflow alarm using the manual’s 15-second outlet-obstruction procedure. Do not use the system if either test fails. Leave the contaminated area immediately if airflow reduces or stops, any component is damaged, breathing becomes difficult, dizziness/distress occurs, or contaminants/irritation are detected.
- Inspect the equipment daily. Replace a broken, blocked or expired filter and replace the pre-filter with the main filter. An installed but unused filter has a manual-stated three-year service life; check its actual expiry. Replace damaged tubing or a leaking/damaged blower.
- Store the complete PAPR system clean and dry at −10 °C to +55 °C and below 90% relative humidity. Allow a battery stored below 0 °C to warm before use; for long storage fully charge it, remove it from the blower and store separately. Clean external surfaces with a soft cloth, without water or solvents.
- The ADF uses a button-cell battery. Keep button cells away from children; suspected swallowing or insertion requires immediate medical attention. Follow the battery and helmet instructions.
In the Box
- 1 × auto-darkening PAPR welding helmet with airduct
- 1 × PAPR blower unit
- 1 × rechargeable lithium-ion battery
- 1 × particulate filter
- 1 × pre-filter
- 1 × spark protector
- 1 × breathing tube
- 1 × waist belt
- Shoulder straps
- 1 × belt strap
- 1 × battery charger
- 1 × airflow tester
- 1 × carry bag
- 1 × operating manual
Helmet Specifications
| Manufacturer part number | U11152 |
| Filter dimensions | 114 × 133 × 9.5 mm |
| Viewing area | 100 × 83.4 mm |
| Optical classification | 1/1/1/1 |
| Arc sensors | 4 |
| Light state | DIN 4 |
| UV / IR protection | DIN 15 |
| Light-to-dark switching | 0.08 ms |
| Dark-to-light delay | 0.1–0.9 seconds |
| Sensitivity / delay adjustment | Levels 1–5, low–high |
| ADF power | Solar cells and replaceable CR2450 battery |
| Shade control | Internal |
| Minimum TIG current | 3 A, manufacturer manual |
| Lens operating temperature | −10 °C to 65 °C |
| Manufacturer-listed eye / face standards | AS/NZS 1337.1 B (high impact); AS/NZS 1338.1 (auto-darkening) |
PAPR Blower Specifications
| Manufacturer-listed filter class | TH3 / P3 |
| Manufacturer-listed respiratory standard | AS/NZS 1716:2012, PAPR-P3 configuration |
| Maximum listed noise | 73 dB |
| Level 1 nominal airflow | 170 L/min (operation section also states a minimum of 165 L/min) |
| Level 2 airflow | 200 L/min |
| Level 3 airflow | 230 L/min |
| Battery | Rechargeable lithium-ion, 4,400 mAh |
| Listed charging time | 3.5 hours |
| System operating temperature | −5 °C to +55 °C |
| System operating humidity | Below 90% RH |
| Specified charger | P-06 03 001; manual lists 100–240 V, 1.5 A |
| Manufacturer-stated inward leakage | Below 0.2% |
Optical Classification Explained
| Class | Manufacturer-described meaning |
|---|---|
| Optical clarity | A clear, crisp view with minimal image distortion. |
| Diffusion of light | Lens uniformity without manufacturing impurities that obscure the view. |
| Shade consistency | Consistent selected shade across the lens, without brighter or darker areas. |
| Angle consistency | A consistent clear view when looking through the lens at different angles. |
Blower Controls and Warning Functions
| Function | Manual description |
|---|---|
| LCD information | Current airflow, selected level, filter condition, battery level and battery temperature. |
| On button | Starts at level 1; further presses cycle level 2, level 3, then level 1. |
| Off button | Hold for at least three seconds. Leave a contaminated area before switching off. |
| Automatic sleep | Manual describes sleep after more than 30 minutes without use; restart using the on button. |
| Warning functions | Current overload, air outlet blockage, overheating, low battery and filter blockage; use the manual’s specific light/LCD/sound chart. |
Manufacturer-listed U11152 replacement parts
| Replacement part | Manufacturer part number |
|---|---|
| Face seal | U11199 |
| Air duct and harness | U11200 |
| Blower | U11201 |
| Breathing tube | U11202 |
| Helmet shell and auto-darkening filter | P0101 |
| Filter cover | P0401 |
| Spark arrestor | P0402 |
| Pre-filter | P0403 |
| Main particulate filter | P0404 |
| Nuisance-odour filter (optional) | U21016 |
| Nuisance-odour pad (optional) | U21017 |
| Waist belt | P0501 |
| Shoulder straps | P0502 |
| Carry bag | P0503 |
| Rechargeable blower battery | P0301 |
| Battery charger | P0603 |
| Airflow tester | P0604 |
| Outer protection lens kit | U21023 |
Product Documents
- UNIMIG U11152 PAPR Operating Manual — Assembly, Service and Exact Parts
- UNIMIG Lithium-Ion Battery Safety Data Sheet — Manufacturer-Linked Cell Information
Warranty
The manual specifies two years for the auto-darkening filter, 12 months for the blower against mechanical or electrical defects, and six months for the U11152 battery, measured from purchase. The manufacturer may repair, exchange a defective part or replace the product at its discretion. Coverage requires intended use and excludes normal wear and tear, misuse, accidents, modification or unauthorised repair. Contact the selling retailer for a claim. These terms do not affect statutory rights.
Specifications
The technical details, grouped for easy checking.
No matching specifications. Try another term or clear your search.
Documents & manuals
Keep the setup and technical information close at hand.
Warranty

Request Pricing or a Quote
Choose the request that suits you and we’ll review the details with this product.