Skip to product information
1 of 7

BOAUR

BOAUR Industrial P2VC Activated Carbon Valved P2 Disposable Respirators - Box of 12 - P2CVAC12i

BOAUR Industrial P2VC Activated Carbon Valved P2 Disposable Respirators - Box of 12 - P2CVAC12i

Regular price $49.50 AUD
Regular price $0.00 AUD Sale price $49.50 AUD
Sale Sold out

GST included. Shipping calculated at checkout.

Pay in instalments

  • Afterpay Afterpay
  • Zip Zip
  • PayPal PayPal Pay in 4

Split your purchase into interest-free instalments at checkout. Terms apply.

SKU:P2CVAC12i

Low stock: 4 left

Quantity
Delivery options

Select your suburb for a delivery estimate. Additional courier options are available at checkout.

Estimates are for this item and quantity only, in AUD excluding GST. Final availability, shipping and GST are confirmed at checkout.

Buy with confidence

Delivery & pickupIn stock · Delivery or Smithfield pickup

In-stock orders are usually processed within 1–3 business days when ready to dispatch. Delivery time is additional and depends on your location and service.

Australia-wide delivery. Available shipping options and costs are shown at checkout.

Free Smithfield pickup. Wait for your Ready for Pickup notification before travelling to the store. Please allow up to 24 hours for your pickup order to be prepared.

Full delivery & pickup policy

Returns & exchanges90 days for eligible unopened items

Change-of-mind returns are available within 90 days of receiving your order for eligible items. Items must be unused, unopened, complete, in original packaging and resellable condition, with proof of purchase.

You pay return shipping for change-of-mind returns. Original shipping is not refunded. Please request approval before sending an item back.

Exclusions include items marked Special Order, gases and cylinders, hazardous materials, chemicals, and custom or cut-to-length items. See the full policy for all exclusions.

Full returns policy & exclusions

Warranty & supportProduct-specific warranty & support

Manufacturer warranties apply where available. See this product’s specifications or contact our team to confirm the applicable warranty.

For a fault or incorrect item, contact our team with your order details and a description of the issue.

Email our support team

Need help choosing?

Call our Smithfield team for product advice and compatibility checks.

View full details

Take a closer look

Product information

Details

BOAUR Industrial P2VC Activated Carbon Valved P2 Disposable Respirators are supplied in a box of 12. Each respirator has a cupped profile, activated carbon filter construction, a blue exhalation valve, two elastic headbands and an adjustable nose bridge. The internal nose foam and mouldable nose clip help position the respirator against the face. Select, fit and use the respirator in accordance with the manufacturer's instructions and AS/NZS 1715.

Key Features

  • P2 disposable respirator: Lightweight, single-use cupped design.
  • Activated carbon: Activated carbon construction identified on the manufacturer's packaging.
  • Valved design: Blue exhalation valve fitted to the respirator.
  • Two elastic headbands: Upper and lower headbands position around the head as shown in the fitting instructions.
  • Adjustable nose bridge: Mouldable nose clip for a snug fit to the shape of the nose and face.
  • Internal nose foam: Foam strip at the nose area, shown in the interior product photograph.
  • No maintenance required: Disposable design; do not clean or reuse.
  • Box of 12: One selling unit contains 12 respirators.

In the Box

  • 12 x BOAUR Industrial P2VC activated carbon valved P2 disposable respirators
  • 1 x BOAUR retail carton with fitting instructions and use warnings

Specifications

Brand BOAUR Industrial
Model P2VC
Product Code / SKU P2CVAC12i
Barcode 0617285160970
Respirator Classification P2, as marked on the product and packaging
Design Cupped, disposable, activated carbon, valved
Headbands Two elastic headbands
Nose Bridge Adjustable mouldable nose clip
Pack Quantity 12 respirators per box
Standard Marked on Packaging AS/NZS 1716:2012
Certification Marking on Packaging Australian Standard, SAI Global; licence number SMK41102
Selection and Use Reference AS/NZS 1715
Operating Temperature -5°C to +50°C
Recommended Storage Temperature +15°C to +30°C
Maximum Age for Use Do not use more than 3 years after the date of manufacture
Maximum In-Use Time 8 hours per respirator; single use only
Country of Manufacture China

Fitting Instructions

  1. Hold the respirator in one hand with the nose-piece at your fingertips, allowing the head straps to hang freely below your hand.
  2. Place the respirator against your face with the nose-piece on the bridge of your nose.
  3. Place the top strap high on the back of your head. Move the bottom strap over your head and position it below your ears.
  4. Use both hands to mould the nose-piece to the shape of your nose for a secure, comfortable fit.
  5. Check the fit by cupping your hands over the respirator and exhaling strongly. If air flows around your nose, tighten the nose-piece. If air escapes around the edges, reposition the straps for a better fit. Check for leakage and tightness before entering a contaminated area.
  6. Read and follow the warnings and restrictions printed on the packaging before use.

Warnings and Use Restrictions

  • Check the condition of the respirator before use. Do not use it if it is not in good condition, is damaged or has been altered in any way.
  • Respirators must be selected, used and maintained in accordance with AS/NZS 1715.
  • Filter efficiency deteriorates in the presence of substances such as oil mists commonly encountered in the workplace.
  • Do not use where oxygen may be deficient (less than 18%).
  • Do not use in atmospheres immediately dangerous to health or life.
  • Do not use in atmospheres containing toxic gases or vapours.
  • Do not use where particulate concentration exceeds 10 times the Australian / New Zealand occupational exposure standard.
  • Do not use more than 3 years from the date of manufacture.

Storage and Disposal

  • Store at +15°C to +30°C in a clean, dry, humidity-proof environment.
  • Do not clean or reuse the respirator.
  • Replace the respirator when the filter medium becomes clogged.
  • Single use only. Maximum in-use time must not exceed 8 hours per respirator.